Series RLC Electrical Impedance and Phase Calculator

Ideal series RLC at one frequency

Electrical Impedance Calculator

Resolve a series resistor, inductor, and capacitor into resistance and net reactance; then calculate complex impedance, magnitude, phase angle, RMS current, resonant frequency, power factor, and the real-reactive-apparent power relationship.

Steady sinusoidal model: components are ideal and connected in series. Parasitics, saturation, temperature rise, tolerances, harmonics, transients, and frequency-dependent loss are not included.

Build the series RLC branch

Set a component to zero to omit it, except capacitance: use the “No capacitor” selection when the branch has none.

Complex impedance result

Series impedance10.000 + j11.173 Ω
Net inductive
Impedance magnitude14.995 Ω
Phase angle+48.17°
Inductive reactance, XL37.699 Ω
Capacitive reactance, XC26.526 Ω
RMS current8.003 A
Displacement power factor0.667 lagging
Series resonant frequency50.329 Hz
Apparent power0.960 kVA
Real power0.640 kW
Reactive power+0.716 kvar

Component ledger

XL = 2π × 60 Hz × 0.100000 H = 37.699 Ω XC = 1 ÷ (2π × 60 Hz × 0.000100000 F) = 26.526 Ω Z = 10.000 + j(37.699 − 26.526) Ω

Impedance has a real part and an imaginary part

R

Resistance

Resistance is the real component. In this ideal series model, it consumes average real power as heat or useful output. Its voltage is in phase with current, and its value is placed on the horizontal axis of the complex plane.

+j

Inductive reactance

An ideal inductor has XL = 2πfL. Its reactance grows with frequency and is positive imaginary impedance. In an inductive branch, current lags voltage, and reactive power is reported positive under the convention used here.

−j

Capacitive reactance

An ideal capacitor has XC = 1/(2πfC). Its contribution is negative imaginary impedance and decreases as frequency rises. In a capacitive branch, current leads voltage, and reactive power is negative under this calculator’s sign convention.

Series RLC model: Z = R + j(XL − XC). Magnitude |Z| = √(R² + X²). Angle θ = atan2(X, R). RMS current = V/|Z|. Displacement power factor = cos θ. Real power P = I²R; reactive power Q = I²X; apparent power S = VI.

Adding the two reactances algebraically is essential. XL and XC oppose one another in a series branch. Adding their magnitudes would overstate impedance. The result calls the branch inductive when XL is larger, capacitive when XC is larger, and resonant when the net reactance is effectively zero.

Worked example: 10 Ω, 100 mH, and 100 µF at 60 Hz

The default inductor is 0.100 H. Multiplying by 2π and 60 Hz gives 37.699 Ω of inductive reactance. The capacitor is 0.000100 F. Taking the reciprocal of 2π × 60 × 0.000100 gives 26.526 Ω of capacitive reactance. Net reactance is therefore +11.173 Ω.

Combining 10 Ω resistance with +j11.173 Ω produces a magnitude close to 14.995 Ω and a positive phase angle near 48.16 degrees. At 120 V RMS, the ideal branch current is about 8.003 A. Resistance divided by impedance magnitude gives a displacement power factor near 0.667, labeled lagging because the net reactance is inductive.

Apparent power is approximately 0.960 kVA. The ideal resistor consumes about 0.640 kW, while the branch exchanges about +0.716 kvar. The squares of real and reactive power reconcile with apparent power through the power triangle, subject to displayed rounding.

Series resonance occurs when XL equals XC. With the entered L and C, that frequency is about 50.329 Hz. At ideal resonance, net reactance is zero and impedance falls to the series resistance. Real components add loss and parasitics, so measured resonance and current will differ.

Frequency can rotate and resize the impedance vector

Below series resonance

XC is larger than XL, making net reactance negative. The vector points below the resistance axis, current leads voltage, and this calculator reports negative reactive power. As frequency approaches resonance from below, the capacitive magnitude shrinks toward the inductive magnitude.

Above series resonance

XL is larger than XC, making net reactance positive. The vector points above the resistance axis, current lags voltage, and reactive power is positive. Far above resonance, the ideal inductor can dominate, although real parasitic capacitance and loss eventually matter.

The resistance input is held constant with frequency. Real winding resistance, dielectric loss, skin effect, proximity effect, magnetic core loss, equivalent series resistance, and leakage can all make the real part frequency dependent. A single ideal point cannot substitute for an impedance analyzer trace or manufacturer curve.

Resonance can create large component voltage or current. Even when source voltage seems modest, series RLC voltage magnification can stress the inductor and capacitor. The tool reports source current and total impedance only; it does not approve component ratings, insulation, thermal performance, or safety.

How to read P, Q, S, and power factor

QuantityMeaning in this ideal sinusoidal branchUnit
Real power PAverage power associated with series resistance, calculated as I²R.W or kW
Reactive power QEnergy exchange associated with net reactance; positive inductive, negative capacitive here.var or kvar
Apparent power SProduct of RMS source voltage and RMS current.VA or kVA
Displacement PFCosine of the fundamental voltage-current phase angle for the ideal sine wave.Dimensionless

Displacement power factor is not necessarily true power factor for a distorted waveform. Rectifiers, switching power supplies, saturation, and nonlinear loads create harmonics. True power factor includes distortion and requires appropriate waveform measurement or harmonic analysis.

Ideal-component limits to check before using the result

  • Inductors: include winding resistance, core material, saturation current, core loss, temperature rise, self-resonant frequency, and insulation rating.
  • Capacitors: include tolerance, ESR, ESL, ripple-current rating, voltage rating, bias dependence, dielectric loss, temperature, polarity, and life.
  • Resistors: include tolerance, power rating, voltage coefficient, temperature coefficient, parasitic L and C, pulse capability, and cooling.
  • Source and wiring: include source impedance, conductor impedance, grounding, protection, available fault energy, and measurement reference planes.
  • Waveform: include harmonics, switching edges, transients, duty cycle, modulation, and startup conditions.

This calculator combines all three elements in one ideal series branch.

Series component voltages do not add as ordinary magnitudes

The same RMS current flows through every element in an ideal series branch. Resistor voltage is IR and is in phase with current. Inductor voltage is IXL and leads current by 90 degrees, while capacitor voltage is IXC and lags current by 90 degrees. The reactive voltages oppose one another as phasors, so the source magnitude is not generally the arithmetic sum of IR, IXL, and IXC.

Near series resonance, IXL and IXC can each be much larger than the source voltage while nearly canceling in the source-voltage phasor sum. That voltage magnification depends on losses and quality factor. It can overstress insulation or components even though total impedance and source voltage appear modest. This calculator intentionally avoids presenting component voltages as approved ratings because ideal values can be dangerously optimistic.

If component stress matters, calculate each complex voltage with realistic ESR, winding resistance, source impedance, and tolerances. Evaluate startup and switching transients separately, and compare peak—not only RMS—values with the manufacturer’s permitted operating envelope.

A reproducible impedance-analysis workflow

  1. Draw the topology. Confirm that components are actually in series. Parallel and mixed networks need admittance or complex-network analysis.
  2. Choose operating frequencies. Include fundamentals, harmonics, sweep endpoints, switching frequencies, and tolerances that matter.
  3. Use effective component data. Replace nominal L, C, and R with frequency-, temperature-, and bias-appropriate values where available.
  4. Calculate complex impedance. Preserve the sign of reactance and use atan2 for the phase quadrant.
  5. Check current and component stress. Evaluate RMS, peak, transient, thermal, voltage, and saturation limits.
  6. Validate the model. Compare with impedance measurements or manufacturer plots over the relevant range.
  7. Document conventions. State RMS or peak values, phasor sign convention, reactive-power sign, frequency, and reference plane.

Frequently asked questions

What is the difference between impedance and resistance?

Resistance is the real component associated with in-phase voltage and current. Impedance includes both resistance and reactance, so it has magnitude and phase. Reactance stores and returns energy and can be inductive or capacitive.

Why is capacitive reactance subtracted?

Under the standard phasor convention used here, inductive reactance is +jXL and capacitive reactance is −jXC. In series they add algebraically, producing j(XL − XC). Their magnitudes oppose rather than simply accumulate.

What happens at series resonance?

Ideal XL equals XC, net reactance becomes zero, and total impedance equals series resistance. Current is then limited by resistance. Real parasitics, component loss, source impedance, and tolerances shift and limit the response.

Can I set resistance to zero?

Yes mathematically, but an ideal resonant branch with zero resistance would imply unbounded current at resonance, which is not physical. Real sources, wires, inductors, and capacitors contain loss and impedance. Use realistic resistance for any stress calculation.

Does the calculator work for parallel RLC?

No. It is explicitly a series model. Parallel networks are most directly combined as admittances, and their resonance and current relationships differ. Do not reuse this series arithmetic for a parallel branch.

Why might measured impedance differ?

Component tolerance, ESR, winding resistance, core loss, ESL, self-resonance, temperature, bias, source and fixture impedance, calibration, frequency, and waveform distortion can all cause differences. The calculator models only ideal nominal values at one frequency.

For a circuit containing resistance, inductance, and capacitance together, check the frequency-dependent result with the RLC circuit impedance calculator.

References

Educational ideal-circuit estimate only. Verify component data, waveform, frequency range, source impedance, thermal limits, protection, and electrical safety before design or testing.

Scroll to Top